Support Center » Knowledgebase » Can I use more than 1 wattson in the same area
 Can I use more than 1 wattson in the same area
Solution It is possible to have more than 1 wattson in the same area. wattson transmits data at 433MHz and each wattson is coded and paired with its own transmitter therefore preventing it from being interrupted by another trasmitter.

If you have 2 or more wattsons in the same area and the wattson/s occasionally reads OUT OF RANGE, then this may be due to two or more transmitters transmitting at the same time (i.e. the red lights on the transmitters are flashing at the same time). To resolve this, either change the transmission mode on one of the transmitters to a slower or faster rate or alternately, remove and then reinsert the batteries on one transmitter so that the transmitters do not transmit simultaneously.